               The  energy  demand  for  space  heating/cooling  and  for  Domestic  Hot  Water  purposes
               (respectively Qh/c.res and QDHW.res) has been consequently calculated for the reference buildings
               as the sum of the energy demand of each apartment composing  each building. Finally, the
                                                                           2
               monthly  and  seasonal  energy  demand  (measured  in  kWh/m ) for  residential  buildings  has
               been computed cluster-by-cluster according to Eq. (1) and (2):

                                             Q        P
                                  E           h  / c .res ,n  n    N  Occ         ) 1 (
                                                 P n
                                     / c
                                    h
                                      .res
                                              Q       P
                                                 DHW
                                  E DHW .res     P ,n  n   N  Occ                 ) 2 (
                                                    n

               where:  Eh/c.res and EDHW.res    are the monthly energy demands of the cluster  for respectively
               heating/cooling  purposes  and  Domestic  Hot  Water  supply;  Pn  is  a  weighting  factor  which
               takes into account the percentage of building having n floors (Figure 4); N is the number of
               building in the cluster and Occ is a parameter taking into account the touristic vocation of
               Italian Islands. In particular, the N value can be assessed as Ares/Atot (where Atot is the total
               residential  built  area  in  the  cluster),  while  Occ  depends  on  the  percentage  of  occupied
               apartment by inhabitant. Moreover, it has been supposed that houses in the island are fully
               occupied during summer months, while during the rest of the year only local people live in
               the island.
               Being very high the touristic vocation of the islands, it must be highlighted that the hotels
               energy demand would have a big impact on the network feasibility. For this reason, they have
               been accurately censed and classified according to the number of beds and to the hotel rating
               system [23]. Present work refers to a study made by Beccali et al. [24] that focuses on energy
               demand of several categories of hotels in Sicily. Table 3 shows energy demand figures for
               heating  and  cooling  for  Isola  del  Giglio.  These  values  have  been  evaluated  introducing  a
               weighting  factor  taking  into  account  the  different  Heating  Degree  Days  between  Sicilian
               Island and Isola del Giglio. Finally, the DHW demand has been assessed according to national
               standard UNI/TS 11300-2:2014 [25].

                                   Table 3. Space heating and cooling demands of hotels

                                          Group I (1-2 star)   Group II (3 star)    group III
                                                                                   (4-5 stars)
                                           Sicily   Tuscany  Sicily   Tuscany  Sicily   Tuscany
                 Heating       Eh.hotel     288      902     835      2143     1620     1805      kWh/bed
                 Cooling       Ec.hotel     389      669     924      1937     778      3761      kWh/bed

                                                            9
   4   5   6   7   8   9   10   11   12   13   14